Keyboard shortcuts

Press ← or → to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

The EHDS EHR system: shared responsibility

Revised 2026-11-17.

Almost every obligation in EU and national health-data law rests on the controller, and where the EHR system is operated on that controller’s behalf, on the processor. Software supplies technical measures. It cannot hold a legal basis, sign a processing agreement, notify a supervisory authority or run a management system.

This page draws that line obligation by obligation for the EHR system that FerroEHR and FerroBRIDGE form together, so you can see which part of the work the software has done and which part stays with you. No openEHR specification governs any of it; the division follows the legal texts each row links.

Warning

Each row links the publisher’s text of the provision it cites. The exact EU and national texts these tables were checked against are vendored in the FerroEHR repository under docs/law/, each at a named consolidation with its digest and licence. This page is not legal advice, and it does not tell you whether your deployment satisfies any obligation.

How to read the tables

Each row names one obligation and links its official source. The middle column is what the software provides, linked to the page of FerroEHR’s book that documents it, or to the open issue when the control is planned rather than shipped. FerroEHR is the store and the logging component of the system, so most measures are FerroEHR’s; a row names FerroBRIDGE where the measure is FerroBRIDGE’s, and FerroBRIDGE’s book documents none of its side yet. The right column is the work that stays with the deploying organisation. A route is written as FerroEHR’s book writes it: {ext} is the base of FerroEHR’s own extensions, outside the openEHR base path, and its admin API page gives it in full.

“Nothing” in the middle column is a real answer and appears wherever it is the true one. The live status of every control FerroEHR declares is on its control matrix, generated from its tracker.

When Cadasto B.V. is also your processor

Cadasto B.V. is the manufacturer of each FerroEHR and FerroBRIDGE release. Whether it is also your processor depends on who runs the deployment:

  • Self-hosted. You run the deployment, or a processor of your choosing runs it for you. Cadasto B.V. supplies the software and processes no personal data on your behalf, so it is not your processor (GDPR Art. 4(8) defines a processor as one “which processes personal data on behalf of the controller”).
  • Hosted by Cadasto B.V. Cadasto B.V. runs the deployment as a service for you. It is then also your processor, and Art. 28(3) has that processing “governed by a contract or other legal act” binding it with regard to you.

Where a row says “the processor”, it means whoever runs the deployment for you. What a product sends out on its own by default is stated in its book: FerroEHR’s is its usage report, which Cadasto B.V. receives as controller for its own purposes.

GDPR

Every row below cites Regulation (EU) 2016/679. The duties in it belong to the controller and the processor. The middle column is only the technical measure FerroEHR supplies toward one of them.

ObligationWhat FerroEHR providesWhat the deploying organisation does
Art. 5(1)(e) storage limitationAudit-trail retention as a configured period, and irreversible physical deletion of an EHR through the admin APISet the retention schedule and execute it; openEHR versions are append-only until you delete the record
Art. 5(2) accountabilityAn audit trail of every access, openEHR’s own contribution and audit chain on every write, and a published conformance recordRetain the evidence and be able to produce it on demand
Art. 6 and Art. 9(2) legal basis and the condition for health dataNothing. Software cannot hold a legal basisEstablish the basis and the Art. 9(2) condition, per purpose, before data is entered
Art. 24 and Art. 25 responsibility, and protection by design and by defaultDeny-by-default authorization, per-EHR access settings, tenancy that fails closed, audit on by defaultChoose the restrictive settings, and document why the chosen configuration is appropriate
Art. 28(3)(e) to (h) what a processor’s contract must let it doThe rights operations in the rows below for (e); the trail, the threat model and the published control documentation for (f); EHR Extract export and physical deletion at the end of service for (g); GET {ext}/admin/config, the trail and verifiable release artifacts as the evidence (h) asks forConclude the processing agreement with whoever operates the deployment, and audit them
Art. 30 records of processing activitiesThe effective configuration as a redacted tree at GET {ext}/admin/config, and this book as a description of what the software doesWrite and maintain the record; only you know the purposes, the recipients and the transfers
Art. 32 security of processingTLS 1.3 with optional mutual authentication, authentication and access control, per-version signing, a tamper-evident audit chain, domain-separated database rolesSupply everything below the application: the database, its backups, the network, the platform. See Cluster hardening
Art. 32(1)(d) regularly testing the measuresA storage-integrity sweep and rebuild, an audit-chain verification query, and a conformance suite that runs against your own serverSchedule the checks, alert on their output, and test your restore
Art. 33(3)(a) and 34(3)(a) breach notification, and the measures that remove the duty to tell patientsThe evidence a breach assessment needs: who read what, when, per patient and per agent, and whether the trail itself is intactDetect, assess and notify within the deadlines. 34(3)(a) lifts the duty to inform patients only where the measures were applied to the data affected, and the application seals national identifiers only, so encryption of clinical content at rest is the database’s and the disk’s. The regulation says nothing about encryption at rest; the measure is yours to choose
Art. 12(3) act on a rights request within one month, electronicallyEvery right below is served by an API call, so the answer is produced in the run that handles the requestStart the clock at receipt, verify the requester, and use the two-month extension only with the reasons the article asks for
Art. 15 and 20 access, a copy, and portabilityThe full record over the openEHR REST API in canonical JSON or XML, the simplified FLAT and STRUCTURED formats, and EHR Extract export for a whole record, which another openEHR system imports directly; the recipients of 15(1)(c) from the per-patient trail searchAuthenticate the data subject and build the patient-facing route. The purposes and the storage period of 15(1) come from your own records, and the portability right reaches consent-based or contract-based processing only (20(3) excludes a public-interest task)
Art. 16 and 17 rectification and erasureVersioned correction with the prior version retained, which is the supplementary statement Art. 16 allows, and physical, irreversible deletion of an EHR and everything it owns, over the primary and the cold archival tier alikeDecide how an erasure request interacts with the medical record-keeping duty and with the Art. 17(3) grounds, record the decision, and reach the backups and the copies outside the CDR
Art. 18 and 21 restriction and objectionA restriction register at whole-EHR or single-object grain, with the marked object refused on every read, query, export, event and write path while its stored rows stay untouched, and its lift stamped rather than erased (#3324); a research objection under Art. 21(6) that removes the record from population queries, exports and the event stream while leaving reads for care untouched (#3325)Decide when to set them, record the ground, hold the restriction in the systems around the CDR, and tell the subject before lifting it
Art. 19 telling each recipient about a rectification, erasure or restrictionAn access record for every read and export naming the agent, the patient, the action, the outcome and the time, so the recipient list is answerable from the trailSend the communications, and name the recipients to the subject on request. The trail records who received data; it notifies nobody, and the regulation sets no retention period for an access log, so how far back the list reaches is the retention you configure
Art. 35 data protection impact assessmentA DPIA page to assess against (processing description, data categories per schema, roles, retention, risk register, shipped controls by issue), records of processing pre-filled with what the software does, and a go-live checklistRun the DPIA and keep it current. It is the controller’s, and no supplier document replaces it
Art. 4(5) pseudonymisationClinical data, demographic data and the EHR id / subject cross-reference live in three separate schemas with non-overlapping NOINHERIT roles, and the server refuses to boot if a role reaches across (the boundary). The cross-reference (which party and which subject identifier name which EHR, the openEHR Service Model’s EHR Index) is resolved only through the linkage pool, every resolution, merge and split an audited linkage access record (#3158, #3345); the clinical schema keeps only the guarded EHR_STATUS subject pair the openEHR wire binds to, and deleting an EHR removes the cross-reference rows naming itGive the demographic and linkage pools their own DSNs, restrict who may resolve, and hold any additional information outside the CDR to the same standard
Art. 89(1) research safeguards, and anonymising where the purpose allows itCohort queries that answer a research question as an aggregate, withheld below the configured small-cell threshold; secondary use leaves the repository through the FerroBRIDGE product to the OMOP CDM, pseudonymised per permit there; the repository’s side of that path (the restriction, objection and retention marks every export honours, a resumable batch export, an access event per export) is planned in #3379Decide whether the purpose can be met without identification and take that route where it can. Until the export lands, secondary use runs on the primary store

EHDS

Regulation (EU) 2025/327 is in force, and its operative obligations apply from the dates its own final provisions carry. No row below claims conformity with any of them.

ObligationWhat FerroEHR providesWhat the deploying organisation does
Chapter II, primary use and the patient’s sight of who accessed their dataAn access trail of every read, write and refusal, searchable by patient and by agent, and a subject-scoped read grant sized for a patient portalBuild the patient-facing access route on that grant and authenticate the person; the product serves one subject’s log to it, never every patient’s
Art. 8 and Art. 11(5), the person’s restriction of access by health professionals and the emergency override in the person’s vital interestsThe restriction of access: recorded on the person’s instruction for a whole EHR or one object, restricted data reads as absent to every professional route, query and export, and only the configured emergency access role declaring an emergency purpose reads it; the access record carries the emergency mark, which the person sees through the subject-scoped retrievalRecord the restriction when the person asks, tell them it may affect their care (Art. 8, second paragraph), configure the emergency role and the agreed emergency codes, and follow the rules and safeguards your Member State sets (Art. 8, fourth paragraph)
Chapter III, EHR systems: the two harmonised software components, technical documentation, the information sheet and instructions for use, the declaration of conformityThe logging component, with a status and evidence per Annex II requirement on the EHDS readiness page; the technical documentation, the information sheet and the instructions for use of each release, kept by Cadasto B.V. as manufacturer. The interoperability component is FerroBRIDGE’s, and the exchange format waits on implementing acts under Article 15(1). From the first FerroBRIDGE release that carries FerroBRIDGE#1377, FerroBRIDGE records each access to its FHIR facade, naming the natural person FerroEHR’s record of the bridge’s call cannot (the access record)Configure the deployment as the instructions for use say, and when you run FerroBRIDGE’s FHIR facade, turn on its [audit] section and run the Audit Record Repository it sends to. A self-hosted deployment of an unmodified release puts Cadasto B.V.’s product into service and leaves the manufacturer’s duties with Cadasto B.V.; in a deployment Cadasto B.V. hosts, it carries them as manufacturer and operator
Chapter IV, secondary useAQL over the stored record and a change-event outbox; the batch export the FerroBRIDGE OMOP load consumes, filtered by the restriction and objection marks, is planned in #3379Deal with the health data access body and carry the data holder’s duties

Chapter II, right by right

Annex II 1.3 asks that the system’s interoperability, safety and security features uphold the rights Chapter II gives natural persons. Most of those rights are exercised through the electronic health data access services each Member State establishes (Art. 4(1)) and the health professional access services (Art. 12); the EHR system stores the data those services read and write. The table names, for each right, the part the EHR system has to provide for the service to serve it, whether FerroEHR provides that part, and what stays with the deployer or the Member State. A part FerroEHR does not provide yet has its own open issue.

RightWhat the EHR system must provideWhat FerroEHR providesWhat the deployer or the Member State serves
Art. 3(1), access to one’s own priority-category data immediately after registrationThe person’s record readable by the access service as soon as it is committedEvery committed version is readable at once over the openEHR REST API and AQL, and a patient-context token reaches one patient’s EHR onlyThe Member State’s access service: identifying the person, the readable consolidated presentation, free of charge
Art. 3(2), an electronic copy in the European exchange formatThe record exported in the exchange formatThe whole record in canonical openEHR and as an EHR Extract; the exchange format is FerroBRIDGE’s interoperability component, and the format itself waits on the Art. 15(1) implementing actsThe download in the access service
Art. 3(3), a Member State’s delay of access until a professional has explained the dataA mark that withholds newly registered data from the person, and from every route they reach it through, until releasedThe delayed access under [access_delay], off by default: a new composition in a listed category reads as absent to any request that may be the person’s, for at most the configured period; professionals read it as before. The treating professional releases it with POST {ext}/ehr/{ehr_id}/versioned_composition/{versioned_object_uid}/access-delay/release, and every hold ends by itself when its period passes. Which request counts as the person’s is the family’s rule in FerroSMART’s ferrohealth-smart. Merged in FerroEHR#4509 for FerroEHR’s next releaseThe Member State’s rule on whether, for which information and for how long (Art. 3(3) with GDPR Art. 23): turn the delay on only where that rule provides it, and list its categories and period. The professional who explains the data and releases it
Art. 4(2), proxy access by an authorised person or a legal representativeAccess decided on a token that names the person whose data is readThe patient scope: a token’s patient claim scopes every request to that person’s EHR, whoever holds the token, and every access record names the actor and the patientThe Member State’s proxy service: the authorisations, their scope and duration, and the representative’s identity
Art. 5, inserting information in one’s own EHR, distinguishable, without altering what professionals enteredWrites by the person marked as theirs, and a refusal of any change by the person to data a professional committedInformation a person inserts: every version a token with only patient/ scopes commits records PARTY_SELF as committer, written by the server whatever the request names, and the contribution list flags it inserted_by_person; an update or deletion by the person of a version anyone else committed is refused with 403. Merged in FerroEHR#4510 for FerroEHR’s next releaseThe access service’s insert route: give it patient/ scopes only and clinicians’ applications user/ scopes, decide which templates the person may write, and show the person’s entries to readers as theirs
Art. 6, rectification requested onlineA correction that keeps what it correctsVersioned correction with the prior version retained, attributed to the committerThe online request in the access service, and the controller’s check with a health professional
Art. 7, portability to another provider, cross-border and to a social security recipientThe record, whole or in part, exported without hindrance from the system’s manufacturerThe REST API, AQL and the EHR Extract, with no fee and no export gate (Annex II 2.6); the exchange format and the cross-border transmission are FerroBRIDGE’s and MyHealth@EU’sTransmitting it to the recipient the person names, one-way for social security (Art. 7(3))
Art. 8 and Art. 11(5), restricting professionals’ access, invisible to them, with the vital-interest overrideA restriction that hides data from professional routes and does not show it exists, and an override that is recordedThe restriction of access and the emergency mark, as in the row aboveAs in the row above
Art. 9, information on every access by health professionals, for at least three yearsA record of every access naming the provider or person, the time and the data accessed, kept three years and retrievable for the personThe access log, a three-year retention floor in every Member State, a subject-scoped retrieval a patient portal can hold, and the syslog and FHIR feeds a notification service can read. While an Art. 3(3) hold lasts, the subject-scoped retrieval leaves out every record that names the held composition, its hold included, and shows them unchanged once the hold ends; the filter is FerroAUDIT’s ehds-logging (FerroEHR#4509)The access service’s presentation and the automatic notifications; the Member State’s exceptions (Art. 9(3)). The hold does not filter the feeds or the change-event stream, so a notification built on either must hold back what is held
Art. 10, opting out of access through the services of Art. 4 and Art. 12, where a Member State’s law provides for itA reversible mark that refuses access through those services, with access in vital interests where the Member State allows it (Art. 10(2))Nothing yet: an opt-out mark is planned in FerroEHR#4516. The Art. 8 whole-EHR restriction is a different right: it reaches every professional route, leaves the person’s own access open, and is invisible to providers, which an opt-out need not beWhether the right exists at all (Art. 10(1)), and its rules and safeguards (Art. 10(2)); where the Member State enforces the opt-out in its own services, nothing reaches the repository

CRA

Regulation (EU) 2024/2847 puts its duties on the manufacturer of a product with digital elements, which for each release of each FerroHEALTH product is Cadasto B.V. The Cyber Resilience Act page states the position.

ObligationWhat FerroEHR providesWhat the deploying organisation does
Art. 13 and Annex I, the essential cybersecurity requirements and the manufacturer’s obligations, from 11 December 2027The CRA risk assessment, point by point against Annex I, with the evidence and the open workRun the newest release, apply security updates, and keep the security environment the intended purpose assumes
Art. 14, reporting actively exploited vulnerabilities and severe incidents, since 11 September 2026Cadasto B.V. notifies the CSIRT and ENISA (complaints, incidents and vulnerabilities)Report what you see to Cadasto B.V.; your own NIS2 and GDPR notifications stay yours
Art. 13(8), the support periodOnly the newest release is supported; security fixes ship in new releases for at least five years after each release, with the end month in the release notesUpgrade to the newest release when one is published; upgrading is free

National law

The sections above apply to every EU deployment. This one is a single country’s law on top of them, three countries so far: the division a deployment reads is “the EU layer, plus my own jurisdiction”. The compliance overview says what adding another takes (National law).

The Netherlands

ObligationWhat FerroEHR providesWhat the deploying organisation does
UAVG Art. 30, the exception for health dataAccess control at the record and attribute level, with every use auditedEstablish that your processing falls inside the exception, per role and per purpose
UAVG Art. 46, processing a national identification numberNational identifiers sealed at rest under the instance’s identifier-protection key in the demographic domain, resolved only through the demographic role, every resolution recorded as a linkage access without the valueHold the statutory authorisation before a BSN enters the store, and restrict who may resolve
Wabvpz Art. 4 to 9, use and verification of the BSNNothing. FerroEHR performs no BSN verification and consults no indexVerify identity and the BSN in your own systems before data reaches the CDR
Wabvpz Art. 15d, electronic access and copy for the patientThe full record over the REST API, and EHR Extract exportAuthenticate the patient and build the route; the CDR has no patient-facing interface
Wabvpz Art. 15e, a record of who made data available and who consulted itAn ATNA trail recording the agent, the patient, the action, the outcome and the time, retrievable per patientRender it for the patient, set retention, and review it
BW Book 7, Art. 454, the medical treatment contract’s record-keeping dutyAppend-only version history, so a correction never destroys the prior versionSet the retention schedule the article requires, and reconcile it with erasure requests

The Netherlands: NEN

The NEN 7510 family is where the split is sharpest. A management-system standard cannot be met by a product at all.

ObligationWhat FerroEHR providesWhat the deploying organisation does
NEN 7510-1, the information security management systemTechnical controls an ISMS can point at, each documented with its residual risk in the threat modelRun the ISMS: scope, risk assessment, policy, internal audit, management review
NEN 7510-2, the controlsAccess control, audit logging, cryptography in transit and for version signatures, supply-chain verificationEverything organisational: personnel, physical security, supplier management, continuity
Certification against NEN 7510Nothing. A product cannot be certified against a management-system standard, and FerroEHR makes no such claimObtain and maintain the certificate for your organisation
NEN 7512, the trust basis for data exchangeMutually authenticated TLS, OAuth2 and OIDC with an enterprise identity provider, SMART App LaunchAgree the trust basis with each counterparty, and operate the certificate estate
NEN 7513, logging actions on electronic patient recordsAn audit trail of every operation including refusals, in FHIR AuditEvent and DICOM PS3.15 form, hash-chained in the databaseMap the recorded fields onto the standard’s own list, set retention, and review the trail

Germany

ObligationWhat FerroEHR providesWhat the deploying organisation does
BDSG § 22 Abs. 2, appropriate and specific measures for health data: traceability, access restriction, pseudonymisation, encryptionVersioned writes with contribution and audit, an access trail, deny-by-default authorization, the pseudonymisation boundary, TLS and sealed identifiersChoose the measures, establish the lit. b ground, and keep the processing under persons bound by professional secrecy
BDSG § 27 Abs. 3, identifying characteristics stored separately for research, rejoined only as the purpose requiresSeparate clinical, demographic and linkage schemas, and cohort queries that cross on identifiers onlyDecide when to anonymise, and hold the balancing test
SGB V §§ 346 to 348, writing treatment data into the ePA once it is held in interoperable formTemplate-structured records, the REST API and EHR Extract exportOperate the transport into the ePA, the connector and the information objects
SGB V § 339 Abs. 3 and § 352, credential-bound access with a log of who accessed what, under a closed role matrixRole- and attribute-based authorization and an access trail naming agent, roles, patient, action and outcomeBind the identity provider to the HBA and SMC-B; the sections bind the ePA, which the CDR is not
SGB V § 309, the TI access log with attempts, three years’ retention and deletion on expiryA trail that records attempts and refusals, retention_days and the retention reaperSet the retention owed; the section binds TI application controllers, not a CDR outside the TI
GDNG § 6, own-data secondary use under pseudonymisation, a rights-and-roles concept, logging and a thirty-year limitPer-domain roles, cohort queries with small-cell suppression, an access record per query with purpose and legal_basis; the export to the FerroBRIDGE OMOP load, where pseudonymisation per permit happens, is planned in #3379Write the rights-and-roles concept, publish the purposes, run the clock, answer subjects from the trail
§ 203 StGB Abs. 3 and 4, necessity-bounded access for those who keep the systems running, and the duty to bind them to secrecySeparate operational surfaces, audited admin reads, one database role per domainBind operators and subcontractors to secrecy in writing, and route support so it needs no standing read of clinical content

Switzerland

Switzerland is not an EU member state: the GDPR rows above do not apply to a Swiss deployment, and the DSG takes their place.

ObligationWhat FerroEHR providesWhat the deploying organisation does
DSG Art. 7, data protection by design and by defaultDeny-by-default authorization, a production deployment profile that refuses missing separationsChoose the restrictive settings where the shipped default favours compatibility
DSG Art. 8 with DSV Art. 3, the minimum security measuresNeed-to-know authorization, one database role per domain, TLS 1.3, attributed versioned writes, an access trail with refusals, signed releasesBackup and restore, patching, breach detection and everything below the application
DSV Art. 4, logging including reads, kept at least a year separately from the processing systemThe trail with every operation and its actor, time and outcome, and forwarding sinks that put a copy outside the CDRForward the trail, set the retention at a year or more, restrict who reads it
DSG Art. 12, the register of processing activitiesThe effective configuration at GET {ext}/admin/config and records of processing pre-filled with what the software doesWrite and maintain the register; DSV Art. 24 leaves no small-organisation exemption for a clinical repository
DSG Art. 22, the impact assessment for large-scale processing of sensitive dataThe DPIA page with the technical description, the risk register and the controls by issueRun the assessment; it is the controller’s
DSG Art. 25 and Art. 28, the right of access within 30 days and data portability in a common electronic formatThe full record over the REST API, the EHR Extract, the published openEHR formats, and a per-patient search of the trail for the recipientsIdentify the requester, render the answer understandably, route it, and meet the deadline
DSG Art. 31 Abs. 2 lit. e, research on anonymised data, with measures against identifiability meanwhileSeparate clinical, demographic and linkage schemas and cohort queries with small-cell suppression; the export to the FerroBRIDGE OMOP load, where pseudonymisation per permit happens, is planned in #3379Decide when anonymisation is possible and hold the research ground
EPDG Art. 10 and EPDV Art. 10 and 12, the certified community’s logging, storage, encryption and residency dutiesIHE ATNA events over ITI-20 with ITI-19 mutual TLS, ITI-81 retrieval, the record in published formats, a self-hosted deploymentFeed the EPD through a certified community; the duties bind the community, which the CDR is not

What this page does not do

It does not tell you whether your deployment satisfies any of these obligations. That depends on your legal basis, your organisation, your infrastructure and your operating practice, none of which a supplier can see.

The companion guidance is in FerroEHR’s book: the DPIA page, the records of processing, the go-live checklist, the compliance overview with the legal sources, and the threat model with the risk that survives each control.